Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Braz. arch. biol. technol ; 51(spe): 103-107, Dec. 2008. tab
Article in English | LILACS | ID: lil-508862

ABSTRACT

The manipulation of unsealed sources in nuclear medicine poses significant risks of internal exposure to the staff. According to the International Atomic Energy Agency, the radiological protection program should include an evaluation of such risks and an individual monitoring plan, assuring acceptable radiological safety conditions in the workplace. The IAEA Safety Guide RS-G-1.2 recommends that occupational monitoring should be implemented whenever it is likely that committed effective doses from annual intakes of radionuclides would exceed 1 mSv. It also suggests a mathematical criterion to determine the need to implement internal monitoring. This paper presents a simulation of the IAEA criteria applied to commonly used radionuclides in nuclear medicine, taking into consideration usual manipulated activities and handling conditions. It is concluded that the manipulation of 131I for therapy presents the higher risk of internal exposure to the workers, requiring the implementation of an internal monitoring program by the Nuclear Medicine Centers.


A manipulação de fontes abertas em Serviços de Medicina Nuclear envolve riscos de exposição externa e contaminação interna. O plano de proteção radiológica das Instalações licenciadas pela CNEN deve incluir a avaliação de tais riscos e propor um programa de monitoração individual de forma a controlar as exposições e garantir a manutenção das condições de segurança radiológica. As recomendações da AIEA apresentadas no Safety Guide RS-G-1.2 sugerem que seja implementado um programa de monitoração interna do trabalhador sempre que houver possibilidade da contaminação interna conduzir a valores de dose efetiva comprometida anual igual ou superior a 1 mSv. Este trabalho apresenta a simulação da aplicação de tais critérios para os radionuclídeos mais utilizados na área de Medicina Nuclear, levando-se em consideração as condições usuais de manipulação das fontes e as faixas de atividade autorizadas pela CNEN. Conclui-se que a manipulação de iodo 131 para fins terapêuticos é a prática que apresentada maior risco de exposição interna dos trabalhadores, requerendo a adoção de um programa de monitoração interna por parte dos Serviços de Medicina Nuclear.

2.
Braz. arch. biol. technol ; 51(spe): 181-184, Dec. 2008. graf
Article in English | LILACS | ID: lil-508874

ABSTRACT

The modification of 99Mo standard metabolism in the presence of MDP would alter the dosimetry of this radionuclide in nuclear medicine patients. Therefore, the objective of this work is to evaluate the influence of MDP in the biodistribution of 99Mo. Wistar rats were divided in two groups of six animals, being inoculated respectively 99Molibdate and 99Mo+MDP via plex ocular. The biodistribution study was carried out after 10 and 120 minutes respectively. The organs were counted with a NaI(Tl) detector. The uptake values did not present significant differences among the groups. An in vitro study through planar chromatography was carried out to determine the affinity between molybdenum and MDP. The results show that 99Mo has low affinity both to propanone and NaCl-0.9 percent solution. However, 99Mo in the presence of MDP presented affinity to NaCl-0.9% solution and low affinity to propanone suggesting that 99Mo was bound to MDP under the conditions of the experiment.


A modificação do metabolismo padrão do 99Mo em presença de MDP levaria a alterações na dosimetria deste radionuclídeo em pacientes de medicina nuclear. Assim, o objetivo deste trabalho é avaliar a influência do MDP na biodistribuição de 99Mo. Ratos Wistar foram divididos em dois grupos de seis animais, sendo inoculados respectivamente com 99Molibdato e 99Molibdato+MDP via plexo ocular. O estudo de biodistribuição foi realizado após 10 e 120 minutos respectivamente. Os órgãos foram contados com detector NaI(Tl). Os valores de uptake não apresentaram diferenças significativas entre os grupos. Foi realizado um estudo in vitro através de cromatografia planar para determinar a afinidade entre o molibdênio e o MDP. Os resultados mostraram que o molibdênio tem baixa afinidade tanto pela propanona quanto pela solução 0.9 por cento de NaCl. Entretanto, o molibdênio em presença de MDP apresentou afinidade pela solução 0.9% de NaCl e baixa afinidade pela propanona, sugering ter ocorrido ligação entre o 99Mo e o MDP nas condições do experimento.

3.
Radiol. bras ; 40(6): 389-395, nov.-dez. 2007. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-471998

ABSTRACT

OBJETIVO: Diferentes métodos são usados para determinar atividade do radioiodo para tratamento de hipertireoidismo (doença de Graves). Alguns não consideram a dose absorvida pela tireóide ou os parâmetros necessários para este cálculo. A relação entre dose absorvida e atividade administrada depende da meia-vida efetiva, da captação do iodo e da massa da tireóide de cada paciente. O objetivo deste trabalho é propor uma metodologia para tratamento individualizado com 131I em pacientes portadores de hipertireoidismo da doença de Graves. MATERIAIS E MÉTODOS: Usou-se um simulador de tireóide-pescoço desenvolvido no Instituto de Radioproteção e Dosimetria contendo solução de 131I, para calibração da gama-câmara e sonda cintilométrica do Serviço de Medicina Nuclear do Hospital Universitário Clementino Fraga Filho da Universidade Federal do Rio de Janeiro. RESULTADOS: O campo de visão colimador-detector apresentou valores compatíveis com o tamanho da glândula para as distâncias de 25 cm (sonda de captação) e 45,8 cm (gama-câmara). Os fatores de calibração (cpm/kBq) foram 39,3 ± 0,78 e 4,3 ± 0,17, respectivamente. O intervalo entre 14 e 30 horas da curva de retenção permite o cálculo de atividade entre dois pontos, para determinação da meia-vida efetiva do iodo na tireóide. CONCLUSÃO: A utilização de equipamentos usualmente disponíveis em serviços de medicina nuclear é viável, tornando esta metodologia simples, eficaz e de baixo custo.


OBJECTIVE: Several methods are utilized for determining the radioiodine activity in the treatment of Graves' disease (hyperthyroidism). Some of this methods do not take into consideration the thyroid absorbed dose or the necessary parameters for this estimation. The association between absorbed dose and administered activity depends on effective half-life, iodine uptake and thyroid mass of each patient. The present study was aimed at developing a methodology for individualized 131I therapy for Graves' disease in patients with hyperthyroidism of the Graves' disease. MATERIALS AND METHODS: A neck-thyroid phantom developed at Instituto de Radioproteção e Dosimetria, containing a standard solution of 131I, was utilized for calibrating the scintillation gamma camera and uptake probe installed in the Department of Nuclear Medicine of the Hospital Universitário Clementino Fraga Filho da Universidade Federal do Rio de Janeiro. RESULTS: The view angle of the collimator/detector assembly presented values compatible with the thyroid gland size for distances of 25 cm (uptake probe) and 45.8 cm (scintillation gamma camera). Calibration factors were 39.3 ± 0.78 and 4.3 ± 0.17 cpm/kBq, respectively. The 14-30-hour interval in the retention curve allows the estimation of activity between two points for determining the effective iodine half-life in the thyroid. CONCLUSION: The utilization of equipment usually available in nuclear medicine clinics is feasible, so this is a simple, effective and low cost methodology.


Subject(s)
Antithyroid Agents , Hormone Antagonists/administration & dosage , Clinical Protocols , Gamma Cameras , Graves Disease , Hyperthyroidism , Hyperthyroidism/drug therapy , Hyperthyroidism/therapy , Thyroid Function Tests , Autoimmune Diseases , Models, Anatomic , Treatment Outcome
4.
Arq. neuropsiquiatr ; 64(3b): 802-806, set. 2006. graf
Article in Portuguese, English | LILACS | ID: lil-437153

ABSTRACT

MOTIVO: O impacto causado pela cefaléia pode impedir a aderência a um programa regular de atividade física. OBJETIVO: Avaliar a prevalência e as características da cefaléia em uma população de praticantes de exercícios físicos. MÉTODO: Cem alunos de uma academia foram avaliados. Todos eram alunos regulares por pelo menos 12 meses e praticavam exercícios aeróbicos pelo menos 3 vezes por semana. Um questionário sobre a prevalência e características da cefaléia foi aplicado a todos aqueles que apresentaram nos últimos 12 meses. O questionário de avaliação de impacto MIDAS também foi aplicado. RESULTADOS: 57 homens e 43 mulheres foram incluídos. Oitenta apresentaram cefaléia no período avaliado. Em 63 por cento a dor era pulsátil. Em 73 por cento da amostra a freqüência de crises situava-se em menos de 1 vez a cada 10 dias. O escore do questionário MIDAS foi inferior a 5 em 83 por cento desses pacientes. CONCLUSÃO: Embora não avaliados por médico e baseado em recall, os dados sugerem alta prevalência de cefaléia com critérios de migrânea. É incerto se a prática regular de exercícios físicos reduz a freqüência de crises ou se os sofredores de cefaléia com baixa freqüência de crises são os que fazem atividade física regular.


BACKGROUND: The burden of headache may impede sufferers from adhering to a routine of physical activity. OBJECTIVE: To evaluate the prevalence and characteristics of headache in a health club population. METHOD: One hundred attendees of a health club were interviewed. They all were regular attendees for the previous 12 months and practiced aerobic exercises no less than 3 times a week. A questionnaire with characteristics of headache was applied to all who had a headache attack during the previous 12 months. MIDAS questionnaire was used as well. RESULTS: 57 men and 43 women were included. Eighty subjects had a headache attack, which was pulsatile in 63 percent of the sufferers. MIDAS was lower than 5 days in 83 percent of the subjects. CONCLUSION: Although retrospective and based on recall, this study suggests that most of the regular exercise practitioners presented clinical characteristics of migraine. It is uncertain whether the regular practice of physical exercise has a role in reducing the impact life or those suffering less are the ones who practice exercise.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Exercise , Headache/epidemiology , Headache/classification , Prevalence , Severity of Illness Index , Surveys and Questionnaires
5.
Braz. arch. biol. technol ; 48(spe2): 215-220, Oct. 2005. ilus, tab, graf
Article in English | LILACS | ID: lil-448912

ABSTRACT

99mTc is a radionuclide widely used for imaging diagnosis in nuclear medicine. In Brazil it is obtained by elution from 99Mo-99mTc generators supplied by the Nuclear Energy Research Institute (IPEN). The elution is carried out in radiopharmacy laboratories located in hospitals and clinics. Depending of the quality of the generator and conditions of use during the elution process, 99Mo can be extracted from the column of the generator, becoming a radionuclidic impurity of the eluate used for the obtention of the radiopharmaceutical to be administered to the patient. 99Mo emits high-energy photons and beta particles and its presence degrades the quality of the image and unnecessarily increases the radiation dose delivered to the patient. An in-vivo measurement technique was developed to verify the occurrence of internal contamination by 99Mo in nuclear medicine patients. Direct measurements were made in a volunteer who underwent myocardial scintigraphy with 99mTc-sestamibi. The results indicated the presence of internal contamination of the patien by 99Mot. The activity was tracked for several days, and an assessment of the radiation dose from the contaminant 99Mo was made.


O 99mTc é um radionuclídeo largamente utilizado em diagnósticos por imagem em medicina nuclear. No Brasil, ele é obtido por eluição de um gerador de 99Mo-99mTc fornecido pelo IPEN. A eluição do gerador é feita nas clínicas onde se realizam os exames. Durante a eluição o 99Mo pode ser carreado da coluna, tornando-se uma impureza radionuclídica do eluato a ser utilizado para a obtenção do radiofármaco administrado ao paciente. O 99Mo emite fótons de alta energia e partículas beta, e sua presença, além de provocar degradação na qualidade da imagem do exame, aumenta desnecessariamente a dose de radiação no paciente. Assim, com o objetivo de verificar a possível ocorrência de contaminação interna por 99Mo em pacientes de medicina nuclear, foi desenvolvida uma técnica de medida in vivo e monitorado um paciente voluntário submetido a cintilografia do miocárdio com 99mTc-sestamibi. Os resultados revelaram a presença de 99Mo no corpo do paciente monitorado.

6.
Rev. bras. med. esporte ; 11(5): 295-298, set.-out. 2005. graf
Article in Portuguese | LILACS | ID: lil-430338

ABSTRACT

Atualmente, os exercícios resistidos (ER) vêm sofrendo uma série de investigações, devido à importância que atingiram no desenvolvimento do condicionamento cardiorrespiratório e neuromuscular. Para prescrição dos ER, algumas variáveis devem ser monitoradas, tais como freqüência cardíaca (FC) e a pressão arterial (PA). A associação entre FC e PA fornece dados para se obter o duplo produto (DP). Essas variáveis foram utilizadas para analisar e comparar as respostas hemodinâmicas do supino reto sentado (SRS) e o supino reto deitado (SRD), sendo realizadas 10 repetições a 65 por cento de uma repetição máxima (1RM). A amostra foi constituída de 14 indivíduos (10 mulheres e quatro homens), idade 23 (± 4 anos), peso corporal 61 (± 7kg) e estatura 168cm (± 5cm). Como material de coleta foram utilizados freqüencímetro Polar MZ1 (Finlândia), esfigmomanômetro Vasquez-Lubry (Alemanha) e um estetoscópio Littman (EUA). Foi utilizado o teste t-Student pareado, para efeito de comparação entre os valores encontrados nas variáveis fisiológicas. A análise estatística teve como critério de significância p < 0,05. Todas as variáveis apresentaram valor médio mais alto no SRS em relação ao SRD. Foram consideradas FC, PAS, PAD e DP pré e pós-exercício. Entende-se que o valor absoluto da PA medido pelo método auscultatório tende a ser inferior àquele registrado dentro da artéria, mas, em situações de testes em exercícios com intensidades diferentes, a variação percentual da PAS apresenta a mesma tendência que o método invasivo. Concluímos, então, que os exercícios de SRS e SRD não apresentaram diferenças significativas em nenhum dos parâmetros fisiológicos estudados. Porém, no SRD observaram-se respostas um pouco abaixo destes parâmetros. Sendo assim, faz-se necessária realização de outros estudos analisando diferentes posições corporais, para que através de comparações possamos estabelecer uma conduta quanto à prescrição destes exercícios.


Subject(s)
Male , Female , Humans , Sports/physiology , Heart Rate/physiology , Physical Education and Training , Physical Endurance , Arterial Pressure/physiology
SELECTION OF CITATIONS
SEARCH DETAIL